AT8404 FASTPATH log messages
Page B - 3 AT8404 CLI Reference Manual
B.2 Utilities
NIM NIM: Attempted event (x), on USP x.x.x before
phase 3
A component issued an interface event during
the wrong initialization phase
NIM NIM: incorrect phase for operation An API call was made during the wrong
initialization phase
NIM NIM: Component(x) failed on event(x) for
intIfNum(x)
A component responded with a fail indication
for an interface event
NIM NIM: Timeout event(x), intIfNum(x)
remainingMask = “xxxx”
A component did not respond before the NIM
timeout occurred
Table 3: System Log Messages
Component Message Cause
SYSTEM Configuration file fastpath.cfg size is 0 (zero)
bytes
The configuration file could not be read. This
message may occur on a system for which no
configuration has ever been saved or for
which configuration has been erased.
SYSTEM could not separate
SYSAPI_CONFIG_FILENAME
The configuration file could not be read. This
message may occur on a system for which no
configuration has ever been saved or for
which configuration has been erased.
SYSTEM Building defaults for file <file name> version
<version num>
Configuration did not exist or could not be
read for the specified feature or file. Default
configuration values will be used. The file
name and version are indicated.
SYSTEM File <filename>: same version (version num)
but the sizes (<version size>-><expected
version size) differ
The configuration file which was loaded was of
a different size than expected for the version
number. This message indicates the
configuration file needed to be migrated to the
version number appropriate for the code
image. This message may appear after
upgrading the code image to a more current
release.
SYSTEM Migrating config file <filename> from version
<version num> to <version num>
The configuration file identified was migrated
from a previous version number. Both the old
and new version number are specified. This
message may appear after upgrading the
code image to a more current release.
SYSTEM Building Defaults Configuration did not exist or could not be
read for the specified feature. Default
configuration values will be used.
SYSTEM sysapiCfgFileGet failed size = <expected size
of file> version = <expected version>
Configuration did not exist or could not be
read for the specified feature. This message
is usually followed by a message indicating
that default configuration values will be used.
Table 4: Trap Mgr Log Message
Component Message Cause
Trap Mgr Link Up/Down: unit/slot/port An interface changed link state.