Management Commands AT8404
AT8404 CLI Reference Manual Page 5 - 48
the kind of clock
5.15 Storage Commands
5.15.1 set board storage connect
This command sets the connection from an AMC to a storage modul. Possible connections are from AMC-B4 to
AMC-B2 (port 2) or AMC-B1 (port 3).
5.15.2 show boardinfo storage
This command displays the the connection from an AMC to a storage modul. Only connections from AMC-B4 are
possible.
5.16 Clock support commands
5.16.1 set board pcie clock
This command sets the kind of used clock. The clock can be a local SSC or local non-SSC.
5.16.2 set board pll
This command sets the PLL configuration. Parameters are
tie (time interval value: normal mode/adjust phase to match reference)
mode (mode: normal operation/free run)
oor (out-of-range select: 40 - 52 ppm/64 - 83 ppm)
reset (reset: normal operation/reset)
source (reference source: none/input CLK1A+B/input CLK2A+B/input CLK3A+B)
Format show boardinfo pcie
Mode Priviledged EXEC
Format set board storage connect amcb4 {amcb1|amcb2}
Mode Priviledged EXEC
Format show boardinfo storage
Mode Priviledged EXEC
Format set board pcie clock {ssc|nssc}
Mode Priviledged EXEC