AT8404 Utility Commands
Page 4 - 61 AT8404 CLI Reference Manual
4.13.3.1 no sflow poller
Use this command to reset the sFlow poller instance to the default settings.
4.13.4 show sflow agent
The sFlow agent collects time-based sampling of network interface statistics and flow-based samples. These are
sent to the configured sFlow receivers. Use this command to display the sFlow agent information.
Example: The following shows example CLI display output for the command.
(switch) #show sflow agent
sFlow Version.................................. 1.3;Broadcom Corp;1.0
IP Address..................................... 10.131.12.66
show sflow pollers
Use this command to display the sFlow polling instances created on the switch. Use “-” for range.
Poll Interval Enter the sFlow instance polling interval. A poll interval of zero (0) disables counter sampling.
When set to zero (0), all the poller parameters are set to their corresponding default value.
The range is 0-86400. The default is 0. A value of N means once in N seconds a counter
sample is generated.
Format no sflow poller {<rcvr-indx> | interval <poll-interval>}
Mode Interface Config
Format show sflow agent
Mode Privileged EXEC
Field Description
sFlow Version Uniquely identifies the version and implementation of this MIB. The version string must have
the following structure: MIB Version; Organization; Software Revision where:
MIB Version: ‘1.3’, the version of this MIB.
Organization: Broadcom Corp.
Revision: 1.0
IP Address The IP address associated with this agent.
Format show sflow pollers
Mode Privileged EXEC
Field Description
Poller Data Source The sFlowDataSource (slot/port) for this sFlow sampler. This agent will support Physical ports
only.
Receiver Index The sFlowReceiver associated with this sFlow counter poller.
Poller Interval The number of seconds between successive samples of the counters associated with this
data source.
Field Description