Kontron JRexplus-LX Manual do Utilizador Página 39

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 60
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 38
KTD-S0001-C Page 35 Crisis Management
JRexplus LX User's Guide
20 Crisis Management
Modifying parameters in the BIOS Setup implies the risk of leaving your system in a unbootable state. In
case this happens two jumper exists to reset the settings to 'Fail-Safe values'.
In case no battery is connected then follow these five steps:
Power down the board
Remove the tagged jumper JP9 (see the picture)
Power up the board and enter the BIOS Setup
Before saving your new settings with 'Save & Exit' put the jumper back
The board should be functional now
In case there is a backup battery for the real time clock:
Power down the board
Switch the second jumper JP8 as depicted and wait for 3 seconds
Put the jumper back as it was before
Then continue with the steps from the no battery case.
Vista de página 38
1 2 ... 34 35 36 37 38 39 40 41 42 43 44 ... 59 60

Comentários a estes Manuais

Sem comentários