Kontron NSW1U IP Network Server Manual do Utilizador Página 72

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 71
NSW1U Network Server—Server Component Replacements
Kontron IP Network Server NSW1U
Product Guide, rev. 1.4 December 2009
72
7. Disconnect the EFP power cable on the EFP board and gently pull the PDB away from the power
supply connectors and the server board power connector. (“B”)
8. Lift the power distribution board from the chassis (“C”).
5.4.2 Installing the Power Distribution Board
1. Lower the replacement power distribution board (PDB) into place. (“A”)
2. Connect the PDB to the server board power connector and the power supply module connectors.
(“B”)
3. Make sure that the PDB is placed over the placement pegs and gently push down. (“C”)
4. Reconnect the EFP board power cable.
5. Re-install the PCI fan assembly and reconnect it.
Figure 55. Removing the PDB
Figure 56. Installing the PDB
A
B
AF000894
C
D
A
B
AF000895
C
D
Vista de página 71
1 2 ... 67 68 69 70 71 72 73 74 75 76 77 ... 109 110

Comentários a estes Manuais

Sem comentários