Kontron NSN2U IP Network Server Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Hardware de computador Kontron NSN2U IP Network Server. Kontron NSN2U IP Network Server User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - Document Revision 1.2

Kontron IP Network Server NSN2U Document Revision 1.2

Página 2 - » Table of Contents «

9 2 Features This chapter briefly describes the main features of the Kontron IP Network Server NSN2U. It provides a diagram of the product

Página 3

99 10.2 Electromagnetic Compatibility Notices FCC (USA) This device complies with Part 15 of the FCC Rules. Operation is subject to the fol

Página 4

100 VCCI (Japan) English translation of the notice above: This is a Class A product based on the standard of the Voluntary Control Council

Página 5

101 11 Appendix C: Getting Help 11.1 World Wide Web Technicians and engineers from Kontron and/or its subsidiaries are available for techn

Página 6

102 Corporate Offices Europe, Middle East & Africa Oskar-von-Miller-Str. 1 85386 Eching/Munich Germany Tel.: +49 (0)8165/ 77 777 Fax

Página 7 - 1 Introduction

10 Table 1NSN2U Server Features Peripheral Interfaces External connections: DB-15 video connector (rear) RJ45 serial Port connector (one

Página 8 - 1.4 Product Accessories

11 NMI Front Panel LEDs Power status Chassis identification System status Fan status HDD activity/fault NIC activity Power Supply Up

Página 9

12 Table X. IP Network Server NSN2U Components Item Description Item Description A RJ45 COM2 port and USB port (2 connectors) H Intel serv

Página 10 - 2 Features

13 Figure 4. NSN2U Server Front View (Bezel Removed) Item Description Item Description A ESD ground strap attachment H Hard drive bay 2 B

Página 11 - Table 1NSN2U Server Features

14 2.3 NSN2U Server Back Panel Figure 6 shows the back panel of the NSN2U server. Figure 6. NSN2U Server Rear View Item Description Ite

Página 12 - 2.1 Server Components

15 2.5 LED/Switch Board The LED/switch board provides input selection switches and LED status indicators for the server system. The LED/s

Página 13

16 A 280-pin Intel® adaptive riser card slot N Fan header B POST code LEDs O Bridge board connector C GCM4 NIC connector P Main power co

Página 14

17 Once PCI add-in cards are installed and the riser card assembly is remounted in the chassis, the cards are accessible from the rear of t

Página 15 - 2.4 Front Panel Board

18 • Dual-port GbE I/O module • Quad-port GbE I/O module 2.11 Remote Management Module 3 RMM3 is implemented on the iBMC on the server bo

Página 16 - 2.7 Optical Drive

www.kontron.com www.kontron.com » Table of Contents « 1 Introduction ... 6 1.1 About this Manual ...

Página 17 - 2.9 Riser Card Assembly

19 • Up to two server board processors • Up to 96 GB of DDR3 memory • Up to eight SAS/SATA hard disk drives • Up to five PCI add-in car

Página 18 - 2.10 Ethernet NIC Ports

20 3 Standard Component Installations and Upgrades 3.1 Before You Begin Before working with your server product, pay close attention to t

Página 19 - 2.13 System Cooling

21 2. While holding the blue button at the top right of the front cover (Figure 10, “B”), slide the cover forward until it stops. 3. Lift

Página 20 - Processors

22 CAUTION: This unit must have both covers installed when it is running to ensure proper cooling. Removing the Front Bezel You need to rem

Página 21 - Upgrades

23 3. Loosen the blue captive thumb screw (Figure 12, “B”) at the rear of the chassis. Notice the guide pins that will be used to re-insta

Página 22 - Re-Installing the Back Cover

24 Removing the Processor Air Duct The processor air duct is black plastic with rubber grommets that reduce vibration. It must be removed

Página 23 - Removing the Front Bezel

25 3.3 Internal System Components Configuration and Installation Procedures This section covers separately-orderable components that must

Página 24

26 Memory Map and Population Rules The nomenclature for DIMM sockets implemented on the Intel® Server Board T5520UR is shown in Table X. Ta

Página 25

27 Channel Independent Mode In Channel Independent mode, multiple channels can be populated in any order (e.g., channels B and C can be pop

Página 26 - Installation Procedures

28 platform is {A1, B1, D1, E1}. {A1, B1} must be identical and {D1, E1} must be identical. However, DIMMs do not need to be identical acro

Página 27 - Memory RAS

www.kontron.com www.kontron.com Re-Installing the Processor Air Duct ... 24 3.3 Internal System Components C

Página 28 - Channel Mirroring Mode

29 • The memory operational mode is configurable at the channel level. Two modes are supported: Independent Channel and Mirrored Channel.

Página 29 - Memory Upgrade Rules

30 To install DIMMs in the T5520UR server board slots, follow these steps: 1. Remove the back chassis cover. For instructions see “Removin

Página 30 - Installing Memory DIMMs

31 1. Remove the back chassis cover. For instructions see “Removing the Back Cover”. 2. Remove the riser card assembly (so the processor

Página 31

32 Figure 15. Cautions for Handling Processors Removing a Processor 1. Loosen the four captive screws on the corners of the heat sink with

Página 32

33 5. Pull the lever and open the load plate all the way. (Figure 18, “A”) Figure 18.Opening the Load Plate 6. Remove the processor. In

Página 33 - Removing a Processor

34 2. Orient the processor with the socket so that the processor cutouts match the socket notches. (Figure 21, “A”) 3. Gently place the p

Página 34 - Installing a New Processor

35 The server board has several 3-pin jumper blocks that can be used to configure, protect, or recover specific features of the server boar

Página 35 - Inserting the Heat Sink

36 Jumper Name Pins System Results J1E7: BIOS Default 1 - 2 These pins should have a jumper in place for normal system operation (Default)

Página 36

37 4 Optional Component Installation Procedures This chapter covers separately-orderable components that you may want to add or replace i

Página 37

38 Figure 24. Cable Routing

Página 38 - Procedures

www.kontron.com www.kontron.com System References ... 56 Cable Routing Reference ...

Página 39

39 Table 4 System Cables Cable Number and Name End 1 Connection End 2 Connection 1: SAS/SATA Backplane Power Power distribution board SAS

Página 40

40 If the drive bay currently has a plastic filler panel instead of a drive carrier, release the panel by squeezing the lever on the right

Página 41

41 4. With the drive carrier locking lever fully open, push the hard drive carrier into the drive bay in the chassis until it stops. (Fig

Página 42

42 Before you can install the SAS/SATA control module, you need to remove the bracket for the 60mm PCI fans. The PCIe flex circuit cable t

Página 43

43 9. If this is the last task you are performing inside the chassis, replace the top front cover. 4.4 Installing a Hardware RAID Module

Página 44

44 5. Unscrew the protective sheet metal cover and install the hardware RAID module using slot and screw. The opening in the top should b

Página 45 - Unit (IBBU)

45 Figure 33. Attaching the IBBU to the RAID Module Secure the IBBU module to the bottom of the RAID module with the three screws in the k

Página 46

46 Figure 35. AC and DC Power Supplies 4.7 Installing a PCI Riser Card The NSN2U server does not ship with a PCI riser card, just the she

Página 47

47 4. Fasten the riser card to the bracket with the two 6/32 screws. (“B” and “C”) Torque screws to 8lbf*in. At this point the riser card

Página 48

48 4.9 Installing an I/O Expansion Module The NSN2U server support three different GbE I/O modules and a SAS I/O expansion module as separ

Página 49

www.kontron.com www.kontron.com 7.2 Problems Following Initial System Installation ... 76 First Steps Checklist ...

Página 50

49 4.10 Installing a Remote Management Module The Remote Management Module (RMM) solution for the NSN2U server has RMM3 in the iBMC on th

Página 51

50 Attach the bracket to the top of the module with the two smaller screws in the package. ( 5. Figure 41, “A”) 6. Attach one end of the

Página 52

51 1. Remove the front chassis cover. For instructions, see “Removing the Front Cover” in Section 3.2. 2. Remove the front panel bezel fr

Página 53

52 Figure 44. Installing the Optical Drive 6. If this is the last task you are performing, replace the front top chassis cover and the fr

Página 54

53 Figure 45. Installing the Z-U130 Drive on the FP Board Installing a Solid State Drive on the Server Board 1. Remove the back chassis c

Página 55 - Equipment Rack Precautions

54 4.13 Installing the Server into a Rack Several different rack mounting kits are available, depending on whether you need 2-post or 4-p

Página 56

55 amperes of protection, you must provide supplemental protection for the server. The overall current rating of a server configured with t

Página 57 - 5.2 Replacing Fans

56 5 Server Component Replacements This chapter covers separately-orderable replacement spare components that you may need to replace in y

Página 58 - Replacing 60mm PCI Fans

57 Replacing 80mm CPU Fans The four 80mm fan assemblies are located behind the SAS/SATA backplane board and HDD bay enclosure. (See Figure

Página 59 - Removing the Bridge Board

58 5.3 Replacing the Bridge Board The NSN2U server bridge board provides the fan tach and the SAS/SATA signal paths between the front pane

Página 60

www.kontron.com www.kontron.com 10.2 Electromagnetic Compatibility Notices ... 99 FCC (USA) ...

Página 61

59 8. Remove the bridge board from the chassis by opening the connector latch clips on the connectors at both ends of the board and freein

Página 62

60 • The bridge board • And because the bridge board, which connects the FP board and the T5520UR server board, must come off, you must a

Página 63

61 5.1. Disconnect the front panel power cable that comes from the SAS/SATA backplane board. 5.2. Disconnect the ganged 80mm CPU fan powe

Página 64

62 Figure 52. Installing the New FP Board Reconnect all of the cables on the FP board. For the locations of each header on the board, see

Página 65

63 If you do not have enough room to access this screw, you will have to remove (or at least slide back) the FP board. For instructions, se

Página 66

64 Removing the Old Power Distribution Board 1. Power down the server and unplug all peripheral devices and the power cable(s). 2. Remove

Página 67

65 Figure 53. Removing the PDB from the Chassis Installing the New Power Distribution Board 1. Connect the edge connectors on the new PDB

Página 68

66 5.7 Replacing the T5520UR Server Board The IP Network Server NSN2U uses the Intel® server board T5520UR. To replace the server board, t

Página 69

67 • To remove memory DIMMs, see “Replacing or Removing Memory DIMMs” in Section 3.3. • To remove the heat sink(s) and processor(s), see

Página 70

68 7. Re-connect the serial port connector to the bridge board and the SATA optical drive cable to the server board. See Figure 24 for the

Página 71

6 1 Introduction 1.1 About this Manual Thank you for purchasing and using the Kontron IP Network Server NSN2U. This manual is for trained

Página 72 - 6 Server Utilities

69 5. Remove the SAS/SATA control module or the SAS/SATA hardware RAID module, if installed. See Section 4.3, “Installing a SAS/SATA Cont

Página 73

70 Installing the New SAS/SATA Backplane Board 1. Install the backplane board on the mounting tabs at the bottom of the drive bay assembly

Página 74 - 6.2 Upgrading the BIOS

71 6 Server Utilities 6.1 Using the BIOS Setup Utility This section describes the BIOS Setup Utility, which is used to change configurati

Página 75 - 6.4 Clearing the Password

72 Key Description ↑ Select Item up - The up arrow is used to select the previous value in a menu item’s option list, or a value field pick

Página 76

73 Key Description If Yes is selected and the Enter key is pressed, all changes are saved and Setup is exited. If No is selected and the En

Página 77 - 7 Troubleshooting

74 3. Locate the “Restore Defaults” jumper (J1E7) as shown in Figure 23. 4. Move jumper (J1E7) from the normal position (pins 1-2) to the

Página 78

75 3. Move the jumper (J1E8) from the normal operation position, “Password Clear Protect”, at pins 1 and 2 to the “Password Clear Erase” p

Página 79 - Power Light does not Light

76 7 Troubleshooting This chapter helps you identify and solve problems that might occur while you are using the Kontron IP Network Server

Página 80

77 1 Are all PCI-X* and PCI Express* (PCIe*) add-in cards fully seated in their slots in the respective riser cards? 1 Are all jumper set

Página 81

78 7.4 Specific Problems and Corrective Actions This section provides possible solutions for specific problems: Try the solutions below in

Página 82 - 7.5 LED Information

7 Appendix C: Getting Help 1.3 What Your Server Includes Your NSN2U server includes the following components: • One 2U chassis • One Int

Página 83

79 Characters are Distorted or Incorrect Check the following: 1 Are the brightness and contrast controls properly adjusted on the video mo

Página 84 - BIOS POST Beep Codes

80 rvers/ip+network+servers/ip+network+server+nsn2u.html for a link to the current version. 1 Try reseating the add-in adapter. The Add-in

Página 85

81 Devices are not Recognized under Device Manager (Windows*OS) The Windows* operating systems do not include all of the drivers for the In

Página 86 - 8 Warranty

82 Table 6. LED Definitions LED Name Function Location Color Notes ID Aid in server identification from the back panel Control panel ID bu

Página 87 - 9.2 Intended Uses

83 Power LED Identify system power state Control panel (on button) Red Off = power off (ACPI S4 or S5) On = power on (ACPI S0) Slow blinkin

Página 88 - Temperature and Ventilation

84 Table 8. Error Beep Codes Provided by an Intel® Remote Management Module Beep Code Reason for the beeps and action to take 1 Control p

Página 89 - 9.3 Safety Cautions

85 8 Warranty This Kontron product is warranted against defects in material and workmanship for the warranty period from the date of shipm

Página 90 - Wichtige Sicherheitshinweise

86 9 Appendix A: Safety Information Warning: Although you may be using this guide or another resource as a reference, before working with

Página 91

87 WARNING: Do not attempt to modify or use an AC power cord set that is not the exact type required. You must use a power cord set that me

Página 92 - Consignes de sécurité

88 per hour for the server. The rack selected and the ventilation provided must be suitable to the environment in which the server will be

Página 93

8 For information about third-party hardware that has been tested and can be used with your system, refer to the IP Network Server NSN2U Te

Página 94

89 in place can damage system parts. To install the covers: 1. Check first to make sure you have not left loose tools or parts inside the

Página 95

90 Versuchen Sie nicht, das mitgelieferte Netzkabel zu ändern oder zu verwenden, wenn es sich nicht genau um den erforderlichen Typ handel

Página 96

91 schließen Sie diese, um ein unerlaubtes Öffnen des Systems zu verhindern. 5. Schließen Sie alle externen Kabel und den AC Stromanschlußs

Página 97

92 d’alimentation du produit. Notez que le commutateur CC de mise sous tension /hors tension du panneau avant n’éteint pas l’alimentation

Página 98

93 ausystème. Le microprocesseur et le dissipateur de chaleur peuvent être chauds si le système a été sous tension. Faites également atte

Página 99 - Certification Information

94 Nótese que el interruptor activado/desactivado en el panel frontal no desconecta la corriente alterna del sistema. Para desconectarla,

Página 100 - Industry Canada (ICES-003)

95 Si el sistema ha estado en funcionamiento, el microprocesador y el disipador de calor pueden estar aún calientes. También conviene tene

Página 101 - BSMI (Taiwan)

96 PASSI DI SICUREZZA: Qualora si rimuovano le coperture del telaio per accedere all’interno del sistema, seguire i seguenti passi

Página 102 - 11 Appendix C: Getting Help

97 Esiste il pericolo di un esplosione se la pila non viene sostituita in modo corretto. Utilizzare solo pile uguali o di tipo equivalente

Página 103

98 10 Appendix B: Regulatory and Certification Information 10.1 Product Regulatory Compliance Product Safety Compliance The IP network ser

Comentários a estes Manuais

Sem comentários