COMe-cSP2 / COMe-cSP2 Connector
15
4.2 Pinout List
4.2.1 General Signal Description
Type
Description
I/O-3,3
Bi-directional 3,3 V IO-Signal
I/O-5T
Bi-dir. 3,3V I/O (5V Tolerance)
I/O-5
Bi-directional 5V I/O-Signal
I-3,3
3,3V Input
I/OD
Bi-directional Input/Output Open Drain
I-5T
3,3V Input (5V Tolerance)
OA
Output Analog
OD
Output Open Drain
O-1,8
1,8V Output
O-3,3
3,3V Output
O-5
5V Output
DP-I/O
Differential Pair Input/Output
DP-I
Differential Pair Input
DP-O
Differential Pair Output
PU
Pull-Up Resistor
PD
Pull-Down Resistor
PWR
Power Connection
nc
Not Connected, Signal not available
Notes: To protect external power lines of peripheral devices, make sure that: the wires have the right diameter to
withstand the maximum available current the enclosure of the peripheral device fulfills the fire-protection
requirements of IEC/EN60950