Kontron NSN2U IP Network Server Manual do Utilizador Página 85

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 84
84
Table 8. Error Beep Codes Provided by an Intel® Remote Management Module
Beep Code
Reason for the beeps and action to take
1 Control panel CMOS clear has been initiated.
1-5-1-1
Processor failure. Reseat or replace the failed
processor.
1-5-2-1
No processor is installed or the CPU 1 socket is
empty. Reseat or replace the failed processor.
1-5-2-3
Processor configuration error or CPU 1 socket is
empty. Reseat or replace the failed processor. In
a two-processor system, make sure the processors
are identical.
1-5-2-4
Front-side bus select configuration error.
1-5-4-2 DC power unexpectedly lost.
1-5-4-3
Chipset control failure.
1-5-4-4
Power control failure.
Vista de página 84
1 2 ... 80 81 82 83 84 85 86 87 88 89 90 ... 102 103

Comentários a estes Manuais

Sem comentários