AM4101 Introduction
ID 1022-5406, Rev. 1.0 Page 1 - 13
P R E L I M I N A R Y
1.7 Standards
The Kontron AMC boards comply with the requirements of the following standards.
Table 1-3: Standards
COMPLIANCE TYPE STANDARD TEST LEVEL
CE Emission EN55022
EN61000-6-3
EN300386
--
Immission EN55024
EN61000-6-2
EN300386
--
Electrical Safety EN60950-1 --
Mechanical Mechanical Dimensions IEEE 1101.10 --
Environmental and
Health Aspects
Vibration
(sinusoidal, operating)
GR-63-CORE
EN300019-2-3
IEC61131-2
IEC60068-2-6
5-150 [Hz] frequency range
1 [g] acceleration
1 [oct/min] sweep rate
10 sweeps/axis
3 directions: x, y, z
Shock (operating) EN300019-2-3
IEC61131-2
IEC60068-2-27
15 [g] acceleration
11 [ms] pulse duration
3 shocks per direction
5 [s] recovery time
6 directions, ±x, ±y, ±z
Climatic Humidity IEC60068-2-78 93% RH at 40°C, non-condensing
WEEE Directive 2002/96/EC Waste electrical and electronic equipment
RoHS Directive 2002/95/EC Restriction of the use of certain
hazardous substances in electrical and
electronic equipment